Cell Biology Practical Investigations, Knowledge Organiser

Knowledge Organiser: Practical Investigations in Cell Biology

Key Terms

  • Magnification: Image size ÷ Real size
  • Resolution: Ability to distinguish two nearby points
  • Iodine: Stains starch/cell walls dark blue-black
  • Methylene blue: Stains nuclei blue
  • Eyepiece graticule: Scale in eyepiece for measuring cells
  • Stage micrometer: Calibration slide for graticule

Must-Know Formulas

  • MIR Triangle: M = I ÷ R (Magnification)
  • I = M × R (Image size)
  • R = I ÷ M (Real size)
  • Unit conversion: 1 mm = 1000 µm
  • % change in mass: ((Final - Initial) ÷ Initial) × 100

Three Required Practicals

PracticalKey SkillIndependent Variable
RPA1: MicroscopyPreparing slides, focusing, biological drawing, magnification calculationObjective lens / magnification used
RPA2: Osmosis in plant tissueCutting equal-sized potato cylinders, measuring % change in massConcentration of sucrose solution
RPA (Mitosis observation)Preparing and staining root tip squash slides, identifying mitosis stagesRegion of root tip observed

Light vs Electron Microscope

FeatureLight microscopeElectron microscope
Maximum magnification~×1,500~×2,000,000
Resolution~200 nm~0.2 nm (TEM)
Living specimensYesNo — specimen must be dead and in a vacuum
Colour imagesYesNo — false colour is added artificially
Cost and sizeLow cost; portableVery expensive; room-sized

Common Mistakes

  • Calculating magnification incorrectly: Always use magnification = image size ÷ actual size, with both measurements in the same unit. Convert mm to µm (× 1000) before dividing to avoid errors by a factor of 1000.
  • Saying staining "magnifies" the cell: Stains (e.g. iodine, methylene blue) make cell structures more visible by adding colour contrast — they do not increase magnification or resolution.
  • Confusing magnification with resolution: Magnification is how many times larger the image is; resolution is the ability to distinguish two separate points. An electron microscope has higher resolution AND magnification than a light microscope.
  • Not describing a fair test in osmosis investigations: When investigating osmosis in potato cylinders, all variables except concentration (e.g. volume of solution, surface area, temperature, time) must be controlled and stated.

Memory Aid

  • Cover I → Image size = M × R
  • Cover M → Magnification = I ÷ R
  • Cover R → Real size = I ÷ M
  • Iodine = dark blue-Inky black (stains starch and cell walls)
  • Methylene blue = blue nucleus (Makes the nucleus visible)

PrepWise is a trading name of A3M Quality Solutions Limited, registered in England and Wales, company number 14959172. Registered office: 202 Stroud Road, Gloucester, GL1 5LA. ICO registration ZC267069.